Active Fire Curtains

Compartmentation and Protected Routes

Fire compartmentation is a fundamental principle in fire safety and building design. It involves dividing a building into separate compartments or fire compartments to prevent the spread of fire, smoke, and hot gases from one part of the building to another. The purpose of compartmentation is to contain a fire within a limited area, limiting its impact and providing occupants with safe evacuation routes.

Fire Curtains are used to form either compartments or protected routes and can be used as alternatives to traditional methods of construction such as non-loadbearing walls, ceilings, doorsets, or glazing systems. Fire Curtains may also be used in a fire strategy to provide flexible compartmentation.

Our Standards

BS8524 - 1:2013

Active fire curtain barrier assemblies

Part 1: Specification

BS8524 - 2:2013

Active fire curtain barrier assemblies

Part 2: Code of practice for installation and maintenance

BS EN 1634 - 3:2005

Smoke control test for door and shutter assemblies

BS EN 12101 - 1:2006

Smoke and heat control systems - Specification for smoke barriers

BS EN 1634 - 1:2014 + A1:2018

Incorporating corrigendum August 2018

Fire resistance test for door and shutter assemblies and openable windows

A1S Group Fire and Smoke Curtains Specification

Product Name

Flameshield 8524

Flameshield 8524 S

Flameshield 8524 Max/S

Flameshield 8524 OV

Flameshield EVO1

Flameshield EVO1 S

Flameshield EVO1 Max/S

Flameshield 1634 OV

Flameshield EW120

Flameshield EW120 S

Flameshield EW120 Max/S

Flameshield Horizontal

British Standards

BS 8524

BS 8524

BS 8524

BS 8524

BS EN 1634

BS EN 1634

BS EN 1634

BS EN 1634

BS EN 1634

BS EN 1634

BS EN 1634

BS EN 1634

Integrity

120 Mins

120 Mins

120 Mins

120 Mins

120 Mins

120 Mins

120 Mins

120 Mins

120 Mins

120 Mins

120 Mins

120 Mins

Radiation W @ 15kw/m2

85

85

Max Width*

5000*

5000*

10000*

30000*

5000*

5000*

10000*

Unlimited*

5000*

5000*

10000*

12000*

Max Height*

6000*

6000*

5000*

6000*

8000*

8000*

6000*

8000*

8000*

6000*

4000*

3000*

Smoke to BS1634-3

N/A

Yes

Yes

N/A

N/A

Yes

Yes

N/A

N/A

Yes

Yes

N/A

Control Panel

P1000

P1000

P1000

P1000

EVO

EVO

EVO

EVO

EVO

EVO

EVO

EVO

Standard Components

Spec Sheets

More Info

More Info

More Info

More Info

More Info

More Info

More Info

More Info

More Info

More Info

More Info

More Info

*Max Width and Max Height can not be aggregated i.e. FS60 T 4000mm wide x 2500mm high and 2000mm wide by 3800mm high is permissible BUT NOT 4000mm x 3800mm. All parameters should always be confirmed with the A1S Group and all permissible parameters are always determined by our Extended Application. For further details see individual product matrices. Parameters are also affected by required fire performance i.e. 1-4 hours and have varying barrel size.

Face Fit Drawing

More Info

More Info

More Info

More Info

More Info

More Info

More Info

More Info

More Info

More Info

More Info

More Info

Reveal Fit Drawing

More Info

More Info

More Info

More Info

More Info

More Info

More Info

More Info

More Info

More Info

More Info

More Info

85

74

85

85

85

74

120

120

120

30

Vertical and Horizontal Fire Curtains.

Fire Curtains

A fire curtain is a specialised fire protection device designed to prevent the spread of fire and smoke within a building. Typically housed in a discreet enclosure and can be automatically or manually deployed in the event of a fire. Here are key features and considerations related to fire curtains.

SELECT YOUR PRODUCT TYPE

Fire and Smoke Curtains

Fire and smoke curtains are specialized fire protection systems designed to control the spread of fire and smoke within a building. These curtains serve distinct purposes in enhancing fire safety.

Smoke Curtains

A smoke curtain is a fire protection device designed to control and limit the spread of smoke within a building during a fire. Unlike traditional fire doors or barriers, smoke curtains are typically deployed in open spaces and are intended to create a barrier that hinders the movement of smoke while allowing for a controlled evacuation.

Fire Curtain Information

Smoke Curtains, Fire Curtains and Fire and Smoke Curtains.

The A1S Group have successfully manufactured and installed our fire curtains in 1000s of UK buildings, from hospitals, offices, homes and schools, to airports, cinemas, stadia, and shopping centres. We have exported fire curtains for some of the world’s most iconic construction projects. Call us today to discuss compliance, quality and competitive pricing UK wide for your project or contact our export team. Our Flameshield range of BS 8524-1 and BS 8524-2 and BS EN 1634-1 fire and smoke curtains offers 120 minutes integrity, leading radiation performance to EW 120, and smoke control to BS EN 1634-3. We have single Flameshield MAX sizes to 10m wide and overlapping curtains to 50m wide. The Flameshield 8524 MAX and Flameshield EVO MAX fire curtain ranges set new standards for extra wide fire curtains with no deflection or sagging, and a bottom bar flush to the head box all with the facility of achieving smoke leakage to BS 1634-3. Our clients have the added peace of mind that our products are fully witness sampled, cyclic tested, and furnace tested by Warrington Exova, Warrington Fire and Element and we hold third party UKAS accredited certification from BOTH IFC and Warrington. Unlike our fire shutter range, fire curtains are not generally covered by harmonised standards, so third party accreditation is an absolute requirement for UK building controls.

A 10 metre wide Flameshield EVO Max fire curtain during C1 Class (500 cycles) development at our factory in Greater Manchester.

Building on our 35 year heritage as specialist steel shutter manufacturers, our fire curtain ranges benefit from precision engineering with products that are sleek, robust and durable. Beyond the testing, certification, and leading fire performance, the entire Flameshield product range can be designed seamlessly into a building’s fabric to provide virtually invisible fire and smoke protection.

Flameshield Horizontal 120 minute integrity fire curtain.

Fast and accurate quotations

  • Flexible lead Times UK wide

  • Up to 120 minutes integrity

  • Compliance explained

  • In house cad design

  • Horizontal curtains

  • Fire curtains

We are highly competitive

  • Testing certification upon request

  • EW 120 minutes fully cyclic tested

  • UK’s widest selection of parameters

  • Experienced surveyors

  • Vertical curtains

  • Smoke curtains