Fire and smoke curtain installed.

Fire Curtains and Smoke Curtains

The A1S Group have successfully manufactured and installed our fire curtains in 1000s of UK buildings, from hospitals, offices, homes and schools, to airports, cinemas, stadia, and shopping centres. Call us today to discuss compliance, quality and competitive pricing UK wide for your project. Our Flameshield range of fire and fire and smoke curtains offers 120 minutes integrity, smoke control and industry leading radiation performance, with the added peace of mind that full witness sampling, cyclic testing, and furnace testing is carried out with Warrington Exova.


Fully compliant Fire Curtains to BS 8524-1 and BS 8524-2 And NOW TESTED TO AN INDUSTRY LEADING EW 120 minutes

  • Fast and Accurate Quotations

  • Flexible lead times UK wide

  • Up to 120 minutes integrity

  • Compliance guaranteed

  • In house Cad Design

  • Horizontal Curtains

  • Fire Curtains

  • We are Highly Competitive

  • Testing certification upon request

  • EW 120 Minutes fully cyclic tested

  • UK’s widest selection of parameters

  • Experienced surveyors

  • Vertical Curtains

  • Smoke Curtains


Current standards

BS 8524-1, BS 8524-2
EN BS 1634-1
EN BS 1634-3
EN BS 12101
Up To 8000mm x 5500mm Single
Up To 5000mm x 8000mm Single
50 metres x 5500mm Overlapping


All our Fire Curtains whether vertical or horizontal are fully compliance-tested and include fail-safe features enabling them to operate even if there’s a power failure. 

And the Flameshield fire curtains have the added benefit of stylish designs which blend neatly with your venue’s decor. End-plates, guides and hoods can even be supplied in a variety of colours for a small additional cost.

Contact a member of our friendly sales team today for a chat about how the A1S Group can meet your project’s fire curtain requirements.

  • Gravity failsafe closes without mains power

  • Provides smoke control

  • Lightweight slimline compact design

  • 2 stage closing operation

  • Compliance tested to maintain building fire safety and integrity in accordance with BS 8524-1 and installed in accordance with BS 8524-2

  • Can be hidden neatly above the ceiling line to assist the building design and aesthetics

  • Voice warning devices available

  • Fully resets after fire test without the need for engineers to attend

  • Low maintenance costs

  • Timed delay closing


Flameshield Fire Curtain

All our fire curtains whether vertical or horizontal are manufactured and produced in accordance with the parameters and technical respects indicated within  specifications, which are submitted to the Warrington Fire Research Establishment.     A1S Group fire curtains are tested and certified to BS 1634-1, BS 1634-3  in accordance with BS 8524-1.

Flameshield Fire Curtain Standard Panel

The panel continuously monitors the normally closed alarm input terminals, if the terminals go open, i.e alarm triggered, the shutter will close under power or via gravity to the fully closed position. Providing the alarm signal is cleared you can reopen the shutter accordingly.

Flameshield Fire Curtain Advanced Panel

The panel continuously monitors the normally closed alarm input terminals, if the terminals go open i.e alarm triggered, the shutter will close under power or via gravity to the fully closed position. Providing the alarm signal is cleared you can reopen the shutter accordingly.